LHP-10 / LHP2-10 / LHP3-10
When the operator is pushed, the valve delivers a nominal flow of 8.8cc to the port.
When the operator is pulled, the valve suctions fluid from the port.
OPERATION
Operating Pressure
207bar; (LHP2-10 , 280 bar)
Displacement
LHP-10: 8.8 cc per stroke
LHP2-10: 4.0 cc per stroke
LHP3-10: 6.0 cc per stroke
Internal Leakage
2 drops/min max. at 138 bar
Temperature
-40
°
F to +250
°
F(-40
°
C to +120
°
C)
Filtration
See page N-1
Fluids
Mineral-based fluids with viscosities of 7.4 to 420 cSt.
Cavity
10-2,See page M-2
Housing Material
6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar
SPECIFICATIONS
LHP3-10
Torque Applied By Operator
SYMBOL
DESCRIPTION
Hand Pump
Hand Pump
J-25
Keta Hydraulics-2023
J
TO ORDER
1 2 3 4
Function
LHP
=Hand Pump
Displacement
2
=4.0cc per stroke
3
=6.0cc per stroke
(
Omit=
8.8 cc per stroke)
1
2
Port Size
Omit=
None
6T
=SAE6
8T
=SAE8
3G
=G 3/8
4G
=G 1/2
4
LHP * 10 * *
3$57180%(5/+3
3$57180%(5/+3
7/8 Nominal Beam inside DIA
Unit=Millimeters
INSTALLATION DIMENSIONS
Size
10
=10-2 Size
3
See page K-4 for detail of
housing
Other port sizes are available
J-26